Hidaka, Akihide
Proceedings of 2014 Nuclear Plant Chemistry Conference (NPC 2014) (USB Flash Drive), 12 Pages, 2014/10
During core cooling at Fukushima Daiichi NPP accident, large amount of contaminated water was accumulated in the basements of reactor buildings at Units 1 to 4. The estimated ratios of I-131 and Cs-137 quantities in water to the core inventories are 0.51%, 0.85% at Unit 1, 74%, 38% at Unit 2 and 26%, 18% at Unit 3, respectively. According to the Henry's law, certain fraction of iodine in water could be released to atmosphere. Many evaluations for I-131 release have been performed so far by MELCOR or the reverse estimation with SPEEDI. The SPEEDI reverse predicted significant release until March 26 while no prediction in MELCOR after March 17. The present study showed that iodine release from accumulated water due to radiolytic conversion from I to I and gas-liquid partition of I may explain the release between March 17 and 26. This strongly suggests a need for improvement of current MELCOR approach which treats the release only from containment breaks.
Hidaka, Akihide
no journal, ,